TABLE OF CONTENTS
01.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
1.1 Upacking
1.2 Optional Accessories
2.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
03
2.1 First Installation
2.2 Internal Sensor Calibration
2.3 ZERO Adjustment
2.4 GAIN Adjustment
2.5 Checking The Adjustment
3.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
07
4.0 Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
07
5.0 Appendix: Available Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
08
5.1 TE Models
52. TP Mocels
5.3 TE-24 Models
5.4 TE-22 Models
5.5 TF Models
5.6 TERX Models
5.7 BTMS Models
6.0 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
-12-
6.0 WARRANTY
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to theoriginal
purchaser that this product is of merchantable quality and confirms in kind and quality
with the descriptions and specifications thereof. Product failure or malfunction arising
out of any defect in workmanship or material in the product existing at the time of
delivery thereof which manifests itself within one year from the sale of such product,
shall be remedied by repair or replacement of such product, at ELECTROMATIC’s
option, except where unauthorized repair, disassembly, tampering, abuse or misappli-
cation has taken place, as determined by ELECTROMATIC. All returns for warranty
or non-warranty repairs and/or replacement must be authorized by ELECTROMATIC,
in advance, with all repacking and shipping expenses to the address below to be borne
by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE
WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR
PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE
NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR
NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER
SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER
REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS
CAUSED BY MANUFACTURER’S OR SUPPLIER’S NEGLIGENCE WITHIN
ONE YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply to you. The duration
of any implied warranty, including, without limitation, fitness for any particular
purpose and merchantability with respect to this product, is limited to the duration of
the foregoing warranty. Some states do not allow limitations on how long an implied
warranty lasts but, not withstanding, this warranty, in the absence of such limitations,
shall extend for one year from the date of invoice.
ELECTROMATIC Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, NY 11516—USA
Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
Every precaution has been taken in the preparation of this manual. Electromatic Equipment Co., Inc., assumes
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of
information contained herein. Any brand or product names mentioned herein are used for identification purpos-
es only, and are trademarks or registered trademarks of their respective holders.
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - TABLE OF CONTENTS

-1-TABLE OF CONTENTS01.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 021.1 Upacking

Page 2 - 1.0 INTRODUCTION

-2-1.0 INTRODUCTIONThese Operating Instructions refer to Model TE sensor; they are also applicable to thefollowing models:TP, TE-24, TE-22, TF, TERX,

Page 3 - 2.0 OPERATION

-3-2.0 OPERATION2.1 First Installation1. Install the sensor at the desired measuring location.2. Connect the sensor with the supplied or existing dis

Page 4 - TE-24 guide rollers:

-4-2.3 ZERO Adjustment1. Install the sensor at the measruing locations in the desired measuring position,using the provided mounting holes.2. Remove t

Page 5 - PPENDIX: AVAILABLE MODELS

-5-7. Insert a screw driver (with a point width of up to 1.9 mm) into the now accessible ZERO opening of the housing and adjust the potentiometer unti

Page 6 - 4.0 PIN ASSIGNMENTS

-6-2.5 Checking the AdjustmentFor general information, refer to section 2.2.Requirements:1. The sensors must be installed at the measuring location.

Page 7 - TENSION SENSORS

TENSION SENSORSOperating InstructionsCHECK•LINE®BY ELECTROMATICELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhurst, NY 11516–U.S.A